Furnace operation steps: how to check what’s wrong with your furnace

If your furnace keeps having issues, this walks you through troubleshooting step by step, and what may be wrong.

5.0 on Google Real Photo Proof Repair-Only HVAC 1-Year Parts & Labor Warranty

← All articles

Quick answer. A furnace starts by running the inducer motor, checking its safety switches, lighting the igniter, opening the gas valve and then starting the blower. Where that sequence stops tells you what may be wrong.

Step 1: Look for a flashing code

Before you take any doors off, look for a flashing light through the small window on the bottom door (the top door if your furnace is installed upside down). Count the flashes, or read the number if your furnace shows one.

Codes usually flash one of two ways: a single count, like 8 flashes, or two sets, like 3 flashes and then 2 flashes, which means code 32. The bottom door should also have a code chart that tells you what the code means. Take a picture of the light and the chart before you go further, since resetting the furnace can clear the code.

Step 2: Reset the furnace

Turn the thermostat off and turn the furnace off for 30 seconds. While you wait, take the top furnace door off. That’s where the burners and the inducer motor are. Some furnaces are installed upside down. If you see the control board and blower instead, put that door back on and take the other door off.

Turn the furnace back on, then set the thermostat back to heat.

Smell gas or a CO alarm goes off? Leave the home and contact local authorities or the gas company.

Step 3: The inducer motor kicks on

Go down to the furnace. You should hear the inducer motor kick on. You’ll feel a slight vibration from it, and you may see it spinning. Keep your hands clear. It can cut you.

The inducer is a small motor attached to a round housing near the exhaust pipe. It pulls combustion gases through the furnace and out the vent.

Inducer didn’t kick on? Make sure the thermostat is set to heat and the furnace is switched on. If it still won’t start, call a professional and give them your flashing code.

Step 4: The pressure switches close

You’ll have one to four pressure switches: small, round switches with wires and rubber hoses attached. The inducer pulls a vacuum, and they all go from open to closed.

Inducer keeps running, but the igniter never comes on? One of your pressure switches is typically stuck open. Turn the furnace off. Take the hoses off the pressure switches and blow through them to clear anything clogging them. Then gently suck and blow on the pressure switches. You may hear a small click as the switch moves. Put the hoses back exactly where they came from, then test the furnace again. If it still won’t light, the switch may be bad, or the inducer may not be pulling enough vacuum. Go on to step 5.

Step 5: The high limit and flame rollouts check out

After the pressure switches close, the furnace checks its other safeties:

  • High limit switch: shuts the burners off if the furnace overheats. It’s usually mounted near the heat exchanger.
  • Flame rollout switches: tiny switches around the burners that detect when a flame goes the wrong direction.
Pressure switches cleared, but still no igniter? Either the high limit switch has gone bad, or a flame rollout switch has detected flames where they shouldn’t be. Call a professional.

Step 6: The igniter turns on

A hot surface igniter glows bright orange in the burner compartment. A spark igniter clicks and makes a small spark. Spark igniters are less common.

Safeties check out, but still no igniter? The igniter itself may be burnt out. With the power off and the igniter cool, look at it. It should be one solid piece with a zigzag. If it’s cracked or separated, it needs to be replaced. An igniter can also fail without a visible crack. A spark igniter may be gunked up and need cleaning or replacing.

Step 7: The gas valve opens and the burners light

Gas flows into the burners, and you’ll see the flames going into the furnace. They should light smoothly and burn steady and blue.

Igniter comes on, but no flames? Check that the gas is on in two places: the shutoff on the gas pipe going into the furnace, which usually has a red handle and is open when the handle is in line with the pipe, and the switch on the gas valve inside the furnace, which should be set to ON. Don’t force a valve that’s hard to turn. If the gas is on in both places and the burners still won’t light, the gas valve is typically stuck or bad and will need to be replaced. Call a professional to inspect it.

Step 8: The flames stay lit

The flame sensor tells the furnace the burners are lit, so the gas stays on. It’s a small metal rod that sits in the flame of one of the burners, usually with a white ceramic base and one wire.

Flames go out within 30 seconds? The flame sensor is the most common cause, and sometimes the hot surface igniter. Turn the power off, remove the flame sensor and clean the rod with steel wool, which works best. Light sandpaper or your shirt will work as a temporary fix, but they can shorten the life of the sensor. Don’t crack the ceramic base or bend the rod, and put it back in its original position. If that still doesn’t work, call a professional. Wiring, a poor ground or an unsteady flame can also keep the furnace from sensing the flame.

If the furnace runs after you clean the flame sensor, you’re good to go. We still recommend taking a picture of the model and serial number, usually on a label inside the furnace, and ordering a new flame sensor. Once a flame sensor needs cleaning, it typically doesn’t have much service life left.

Step 9: The blower motor kicks on

After roughly 30 seconds of the flames warming up the furnace, the blower motor kicks on. That’s the bigger fan that pushes warm air through your ducts. The delay varies by furnace, and some take longer.

Blower never comes on? Turn the furnace off and call a professional. Without the blower, the furnace overheats and the high limit shuts the burners off.

Furnace turns on and shuts right back off? See Why does my furnace turn on for a few seconds and then shut off?