Step 1: Look for a flashing code
Before you take any doors off, look for a flashing light through the small window on the bottom door (the top door if your furnace is installed upside down). Count the flashes, or read the number if your furnace shows one.
Codes usually flash one of two ways: a single count, like 8 flashes, or two sets, like 3 flashes and then 2 flashes, which means code 32. The bottom door should also have a code chart that tells you what the code means. Take a picture of the light and the chart before you go further, since resetting the furnace can clear the code.
Step 2: Reset the furnace
Turn the thermostat off and turn the furnace off for 30 seconds. While you wait, take the top furnace door off. That’s where the burners and the inducer motor are. Some furnaces are installed upside down. If you see the control board and blower instead, put that door back on and take the other door off.
Turn the furnace back on, then set the thermostat back to heat.
Step 3: The inducer motor kicks on
Go down to the furnace. You should hear the inducer motor kick on. You’ll feel a slight vibration from it, and you may see it spinning. Keep your hands clear. It can cut you.
The inducer is a small motor attached to a round housing near the exhaust pipe. It pulls combustion gases through the furnace and out the vent.
Step 4: The pressure switches close
You’ll have one to four pressure switches: small, round switches with wires and rubber hoses attached. The inducer pulls a vacuum, and they all go from open to closed.
Step 5: The high limit and flame rollouts check out
After the pressure switches close, the furnace checks its other safeties:
- High limit switch: shuts the burners off if the furnace overheats. It’s usually mounted near the heat exchanger.
- Flame rollout switches: tiny switches around the burners that detect when a flame goes the wrong direction.
Step 6: The igniter turns on
A hot surface igniter glows bright orange in the burner compartment. A spark igniter clicks and makes a small spark. Spark igniters are less common.
Step 7: The gas valve opens and the burners light
Gas flows into the burners, and you’ll see the flames going into the furnace. They should light smoothly and burn steady and blue.
Step 8: The flames stay lit
The flame sensor tells the furnace the burners are lit, so the gas stays on. It’s a small metal rod that sits in the flame of one of the burners, usually with a white ceramic base and one wire.
If the furnace runs after you clean the flame sensor, you’re good to go. We still recommend taking a picture of the model and serial number, usually on a label inside the furnace, and ordering a new flame sensor. Once a flame sensor needs cleaning, it typically doesn’t have much service life left.
Step 9: The blower motor kicks on
After roughly 30 seconds of the flames warming up the furnace, the blower motor kicks on. That’s the bigger fan that pushes warm air through your ducts. The delay varies by furnace, and some take longer.
Furnace turns on and shuts right back off? See Why does my furnace turn on for a few seconds and then shut off?
Need furnace repair?
The $110 diagnostic is credited toward approved repairs.