Troubleshooting

Why does my furnace turn on for a few seconds and then shut off?

5.0 on Google Real Photo Proof Repair-Only HVAC 1-Year Parts & Labor Warranty

← All articles

Quick answer. If your furnace starts and shuts off after a few seconds, the problem could be a pressure switch, igniter, flame sensor, gas valve or safety switch. What happens before it shuts off helps narrow down the cause.

1. Look for a flashing code

Before you take any doors off, look for a flashing light through the small window on the bottom door (the top door if your furnace is installed upside down). Count the flashes, or read the number if your furnace shows one.

Codes usually flash one of two ways: a single count, like 8 flashes, or two sets, like 3 flashes and then 2 flashes, which means code 32. The bottom door should also have a code chart that tells you what the code means. Take a picture of the light and the chart before you go further, since resetting the furnace can clear the code.

2. Remove the top door

Start by removing the top door of the furnace. Behind it you should see the burners and the inducer fan. Some furnaces are installed upside down. If you see the control board and blower instead, put that door back on and take the other door off.

The inducer is a small motor attached to a round housing near the exhaust pipe. It pulls combustion gases out of the furnace.

Smell gas or a CO alarm goes off? Leave the home and contact local authorities or the gas company.

3. Reset the system

Turn the thermostat off. Turn the power to the furnace off for 30 seconds, using the switch near the furnace. Turn the furnace back on, then call for heat from the thermostat.

4. Listen for the inducer

Go down to the furnace. You should hear the inducer motor kick on, and you will see the top or center of the inducer spinning.

5. Watch for the igniter

After the inducer kicks on, you will see the igniter go off in the burner compartment. Your furnace has one of two kinds:

  • Hot surface igniter: a small element near the burners that glows bright orange.
  • Spark igniter: makes a small electrical spark near the burners.

If you do not see the igniter go off, that typically means one of your pressure switches is not closing. A pressure switch may be bad or clogged, or the inducer is not pulling enough vacuum to close the pressure switches.

Pressure switches are small, round switches with wires and a rubber hose attached. The hoses run to the inducer or another part of the furnace.

Shut the furnace down, remove the hoses going to the pressure switches, and blow out all of the hoses. Then blow and suck on the pressure switches. You should hear a little click. You can sometimes free a stuck pressure switch this way.

6. Check the high limit and flame rollout switch

If the pressure switches weren’t the problem, one of these safeties may be open:

  • High limit: a small metal switch, usually near the heat exchanger. It shuts the burners off if the furnace gets too hot.
  • Flame rollout switch: a small round switch near the burners.

The high limit resets on its own: leave the furnace off for 10 minutes, then turn it back on, and the furnace should kick back on.

7. Listen for the gas valve and watch for flames

After the igniter goes off, the gas valve opens and the burners light. Some gas valves open without a click you can hear.

If you do not see any flames at all, the gas pressure to the furnace may be off, the gas valve may be turned off, or the gas valve may not be operating properly.

8. The flame goes out within 30 seconds

That is typically a dirty flame sensor, and it will need to be cleaned or replaced.

The flame sensor is a small metal rod that sits in the flame of one of the burners, usually with a white ceramic base and one wire. If it can’t sense the flame, the furnace shuts the gas off.

9. It runs a couple of minutes, then kicks off

That could be the high limit shutting it off, or sometimes a pressure switch shutting it off after it has run for a few minutes.

Tip: Check your air filter. A clogged filter can make the furnace overheat and trip the high limit. Make sure the supply and return vents aren’t blocked, too.

If you already cleaned the pressure switches, or if the furnace is kicking off because of the high limit, we recommend calling a professional to find out why that’s happening.

For the full startup sequence, see Furnace operation steps: how to check what’s wrong with your furnace.